Menu généré depuis test.html

Electrical scalpel Surtron 400 HP

18421.20
Description du produit

Surtron LED SURTRON 400 HP can be used for simultaneous monopolar and bipolar surgery in applications requiring high precision and reliability. UNDERWATER CUTTING AND COAGULATION DUAL ACTIVITY - Two output channels for monopolar cutting - Two independent setting and output channels for more frequent monopolar coagulation. CONTROLLED CUTTING PROCEDURES - Cutting currents for an eschar-free incision - Cutting current with selectable coagulant property for bleeding-controlled dissection - Low capacitive coupling by current endoscopic procedures Slow BLEND DOUBLE SUBSIDIARY COAGULATION PROCEDURES - SPEEDY Coag DEEP ** * and two operators - SPRAY COAG can be performed using a handpiece or foot pedal WIDE BIPOLAR CHARACTERISTICS - Bipolar cut with bleeding control - Slow BLEND cutting current - Automatic start and stop activated separately TOTAL SAFETY FOR PATIENT AND SURGEON - The acceptability of the contact impedance between the patient's body and the neutral plate is constantly checked by the SPEC electronic skin plate control. - Continuous monitoring of leakage current - Automatically compensated mains voltage change before RF power start-up CUSTOMISED PROCEDURES - Independent choice of coagulation currents and power levels for each of the two operators - Ten personal procedures that can be configured and immediately recalled CONTROL OF EXTENSIONS AND CONNECTION OF SIGNALS - outputs for connection of controlled argon plasma units and smoke extractor AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP - Automatic check of the functionality of the complete electronic drive and connected accessories and coded report of detected faults. * Coag SPEEDY is also known as Fulgurate or Forcé. ** Coag DEEP is also known as Pin Point, Dessicate or Soft. SPECIFICATIONS Code 10400.902 Maximum monopolar pure CUT output power: 400 W - 300 Ω Maximum monopolar cut-coag CUT80% output power: 300 W - 300 Ω Max. monopole cut-coag output power CUT60%: 250 W - 300 Ω Maximum monopole output power CUT40%: 200 W - 300 Ω Maximum monopole cut-coag output power ENHANCED: 250 W - 500 Ω Maximum monopole output power coag cut BLEND: 250 W - 300 Ω SPEEDY coag monopolar maximum output power: 120 W - 500 Ω Maximum power output of monopolar coagulator DEEP: 120 W - 200 Ω Maximum output power of SPRAY monopolar coagulator: 120 W - 2000 Ω Maximum output power of SPRAY ARGON monopolar coagulator: 120 W - 2000 Ω Maximum bipolar CUT output power: 120 W - 50 Ω Maximum bipolar cut-coag CUT80% output power: 120 W - 50 Ω Maximum bipolar cut-coag CUT60% output power: 120 W - 50 Ω Maximum bipolar cut-coag output power CUT40%: 100 W - 50 Ω Maximum bipolar cut-coag output power BLEND: 120 W - 150 Ω Maximum output power bipolar coag COAG: 120 W - 50 Ω Tank sealing: 200 W - 50 Ω Working frequency Monopolar / Bipolar: 425 kHz / 525 kHz Patient circuit: F Selectable input voltage: 115 - 230 Vac Mains frequency: 50 - 60 Hz Electrical input power: 1000 VA Dimensions WxHxD: 470x150x400 mm Weight: 17.5 kg CONTROLS Patient/plate circuit control Output power control Self-check control H.F. leakage current control Mains fluctuation compensationSECURITY EN60601-1 EN60601-1-2 EN60601-2-2 Enclosure protection level: IP21 Electrical classification: CF MDR 2017/745/EU Class: II b Complies with safety standards: EN 60601-1, EN 60601-1-2; EN 60601-2-2. Electrical classification: I CF. Technical data Réf. IBSUR100

Your cart Close

"*" indicates required fields

Please enter a number from 0 to 1000.